Blog

ELISA Kit for Charcoat Leyden Crys

  • Product name: Charcot Leyden Crystal Protein (CLC), ELISA kit
  • Full Product Name: Charcot Human Leyden Crystal Protein (CLC) ELISA Kit
  • Product synonym names: LGALS10; LPPL; Eosinophil lysophospholipase; Lisolecithin acyl hydrolase; Galectin 10
  • Product gene name: Elisa CLC Kit
  • OMIM: 153310
  • Species reactivity: Human

Specificity

This assay has high sensitivity and excellent specificity for the detection of Charcot Leyden crystal protein (CLC). No significant cross-reactivity or interference was observed between Charcot Leyden crystal protein (CLC) and its analogs.

Test type: Double Antibody Sandwich

Samples Serum, plasma, tissue homogenates, cell lysates, cell culture supernatants, and other biological fluids

Detection range: 0.312-20ng / mL

Sensitivity: <0.116 ng / ml

Request

Enzyme-linked immunosorbent assay for antigen detection.

Intra-assay precision (precision within an assay)

3 samples were tested with low, medium, and high-level Charcot Leyden crystal protein (CLC) 20 times on one plate, respectively.

Inter-assay precision (precision between assays)

3 samples were tested with low, medium, and high-level Charcot Leyden crystal protein (CLC) on 3 different plates, with 8 replicas on each plate.

CV (%) =: SD / media X100

Intra-assay: CV <10%

Intense: CV <12%

Preparation and storage

The stability of the kit is determined by the rate of loss of activity. The loss rate for this kit is less than 5% within the expiration date under proper storage conditions. To minimize the further influence on performance, operating procedures and laboratory conditions, especially ambient temperature, air humidity, and incubator temperature, must be strictly controlled. It is also strongly suggested that the entire test be performed by the same operator from start to finish.

ISO certification

Manufactured in an ISO 9001: 2008 and ISO 13485: 2003 certified laboratory.

Supply chain verification

Lab-made with traceable raw materials. Generally, bulk orders can be prepared to customer specifications, please inquire.

Product note

Information selected from the online data sheet is extracted from bioinformatics databases, occasionally resulting in ambiguous or irrelevant product information. It is the customer’s responsibility to review, verify and evaluate the information to make sure it matches their requirements before purchasing the kit. The essays in our ELISA kit are dynamic research tools and can sometimes be updated and improved.

If the format of this assay is important to you, please request the current manual or contact our technical support team with a pre-sale consultation before placing an order. We will confirm the current details of the trial. We cannot guarantee that the sample manual posted online is the most current manual, it is intended to serve as an example only. See the instructions for use provided with the test kit for precise details.

Other notes

Occasionally, small volumes of the ELISA CLC kit vials may become trapped in the product vial seal during shipping and storage. If necessary, briefly centrifuge the vial in a benchtop centrifuge to dislodge any liquid on the lid of the container. Some products may need to be shipped with dry ice and an additional fee may apply for dry ice.

Search terms for purchasing CLC

MBS2021915 is a ready-to-use microwell plate ELISA (Enzyme-Linked Immunosorbent Assay) kit for testing the presence of target analytes from the Charcot Leyden Crystal Protein (CLC) ELISA Kit in biological samples. The concentration gradients of kit standards or positive controls provide a theoretical detection range of the kit in biological research samples containing CLC.

The analytical biochemical ELISA technique of the MBS2021915 kit is based on CLC antibody-CLC antigen interactions (immunosorbent) and an HRP colorimetric detection system to detect CLC antigen targets in samples. The ELISA Kit is designed to detect native, non-recombinant CLC. Appropriate sample types may include secretions and undiluted body fluids and/or tissue homogenates. Quality control trials evaluating reproducibility identified the intra-assay CV (%) and inter-assay CV (%).

Related Product Information for Elisa CLC kit

The test principle applied in this kit is the Sandwich Enzyme Immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Charcot Leyden crystal protein (CLC). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific for Charcot Leyden crystal protein (CLC). Horseradish peroxidase (HRP) conjugated avidin is then added to each well of the microplate and incubated.

After adding TMB Substrate Solution, only wells containing Charcot Leyden Crystal Protein (CLC), Biotin-Conjugated Antibody, and Enzyme-Conjugated Avidin will show a color change. The enzyme-substrate reaction is terminated by adding a sulfuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm ± 10 nm. The concentration of Charcot Leyden Crystal Protein (CLC) in the samples is then determined by comparing the D.O. of the samples to the standard curve.